Perkins Engines in MPS Diesel Generators
MPS generators run on 25 Perkins diesel engines, from the 3-cylinder 403A-11G1 in the MPS 10 (10 kVA) to the 16-cylinder V16 4016-61TRG3 in the MPS 2500 (2,500 kVA). Find your engine below to see which MPS generator uses it, its rating and its Perkins data sheet.
Which MPS generator uses which Perkins engine
Engine details from the MPS data sheets. Tap a model for fuel use, dimensions and noise, or open the Perkins engine data sheet.
| Perkins engine | Cylinders | Aspiration | MPS generator | Engine data sheet |
|---|---|---|---|---|
| 403A-11G1 | 3, in-line | Naturally aspirated | MPS 10 (10 kVA) | |
| 403A-15G1 | 3, in-line | Naturally aspirated | MPS 15 (15 kVA) | |
| 403A-15G2 | 3, in-line | Naturally aspirated | MPS 16.5 (16.5 kVA), MPS 17 (17 kVA) | |
| 404A-22G1 | 3, in-line | Naturally aspirated | MPS 22 (22 kVA) | |
| 1103A-33TG1 | 3, in-line | Turbocharged | MPS 50 (50 kVA) | |
| 1104A-44TG2 | 3, in-line | Turbocharged | MPS 88 (88 kVA) | |
| 1104C-44TAG2 | 4, in-line | Turbocharged | MPS 110 (110 kVA) | |
| 1106A-70TG1 | 6, in-line | Turbocharged | MPS 150 (150 kVA) | |
| 1106A-70TAG2 | 6, in-line | Turbocharged | MPS 165 (165 kVA) | |
| 1106A-70TAG4 | 6, in-line | Turbocharged | MPS 220 (220 kVA) | |
| 1206A-E70TTAG3 | 6, in-line | Turbocharged | MPS 275 (275 kVA) | – |
| 1506A-E88TAG5 | 6, in-line | Turbocharged | MPS 330 (330 kVA) | |
| 2206A-E13TAG2 | 6, in-line | Turbocharged | MPS 385 (385 kVA), MPS 400 (400 kVA) | |
| 2206A-E13TAG3 | 6, in-line | Turbocharged | MPS 440 (440 kVA), MPS 450 (450 kVA) | |
| 2506A-E15TAG2 | 6, in-line | Turbocharged | MPS 550 (550 kVA) | |
| 2806A-E18TAG1A | 6, in-line | Turbocharged | MPS 660 (660 kVA) | |
| 2806A-E18TAG2 | 6, in-line | Turbocharged | MPS 700 (700 kVA), MPS 715 (715 kVA) | |
| 2806A-E18TTAG4 | 6, in-line | Turbocharged | MPS 770 (770 kVA) | |
| 4006-23TAG3A | 8, in-line | Turbocharged | MPS 1000 (1,000 kVA) | |
| 4008TAG2A | 8, in-line | Turbocharged | MPS 1100 (1,100 kVA) | |
| 4012-46TAG2A | 12, V12 | Turbocharged | MPS 1650 (1,650 kVA) | |
| 4012-46TAG3A | 12, V12 | Turbocharged | MPS 1875 (1,875 kVA) | |
| 4016TAG1A | 16, V16 | Turbocharged | MPS 2000 (2,000 kVA) | |
| 4016-61TRG2 | 16, V16 | Turbocharged | MPS 2250 (2,250 kVA) | |
| 4016-61TRG3 | 16, V16 | Turbocharged | MPS 2500 (2,500 kVA) |
Frequently asked questions
Which Perkins engine does my generator need?
Start from the load, not the engine. Work out the kVA you need, pick the MPS model with the right prime or standby rating, and the engine comes with it. Not sure of your load? Read prime vs standby ratings or send us your load list.
What do the letters in a Perkins engine code mean?
The first digits give the engine series and size, for example 1104 is a 4-cylinder engine from the 1100 series and 2206 a 6-cylinder from the 2200 series. A “G” marks a generator engine, and a “T” means turbocharged, as in the 1103A-33TG1. Check the Perkins data sheet in the table for full details.
Do you service and supply parts for Perkins engines?
Yes. MPS provides maintenance contracts, repairs and spare parts for Perkins-powered generators across the UAE, including sets from other builders.
I have an engine code from an old generator. Can you match it?
Send us the engine code and kVA from the nameplate and we’ll tell you the closest MPS replacement set, or quote parts and service for the existing one.
Need a Perkins-powered generator?
Tell us the load, site and timeline, and we’ll recommend the right model.