Cummins Diesel Generators, 22 to 2,500 kVA
Cummins builds 50 Hz diesel generator sets from 22 kVA to 2,500 kVA standby, each with a Cummins engine and a Cummins PowerStart or PowerCommand controller. Tell us your load and site, and MPS will quote the right Cummins set, installation and maintenance.

Cummins 50 Hz range
Ratings in kVA at 50 Hz, 1500 rpm, from Cummins’ International 50 Hz rating card (August 2025). Canopy weight is shown where Cummins publishes it. Open a model for its full specifications.
| Model | Prime kVA | Standby kVA | Cummins engine | Alternator | Controller | Canopy weight (kg) |
|---|---|---|---|---|---|---|
| C22D5 * | 20 | 22 | X2.5-G2 | S0L2-G1 | PS0600 | 1,056 |
| C28D5 | 25 | 27.5 | X2.5-G2 | S0L2-M1 | PS0600 | 1,079 |
| C38D5 | 35 | 38 | X3.3-G1 | S1L2J1 | PS0600 | 1,232 |
| C55D5L | 50 | 55 | 4BTAA3.3-G13 | UCI224C | PS0600 | – |
| C90D5 | 82 | 90 | 6BTA5.9-G5 | UCI224G | PC 1.2 | 2,213 |
| C110D5 | 100 | 110 | 6BTA5.9-G5 | UCI274C | PC 1.2 | 2,232 |
| C150D5 | 136 | 150 | 6BTAA5.9-G6 | UCI274E | PC 1.2 | 2,176 |
| C220D5 | 200 | 220 | 6CTAA8.3-G7 | UCI274H | PC 1.2 | – |
| C275D5 | 250 | 275 | QSL9-G5 | UCDI274K | PC 1.2 | 3,924 |
| C330D5 | 300 | 330 | QSL9-G5 | HC4D | PC 1.2 | 4,147 |
| C400D5 | 360 | 400 | QSG12-G1 | HC4F | PC 2.2 | – |
| C450D5 | 409 | 450 | QSG12-G1 | HC5C | PC 2.2 | – |
| C550D5 | 500 | 550 | QSZ13-G10 | S5L1D-D41 | PC 2.2 | – |
| C700D5 | 640 | 706 | VTA28-G5 | HC5F | PC 3.3 | – |
| C900D5 | 820 | 900 | QSK23-G3 | S6L1D4 | PC 3.3 | – |
| C1100D5 | 1,000 | 1,110 | QST30-G4 | S6LIDD4 | PC 3.3 | – |
| C1400D5 | 1,250 | 1,400 | KTA50-G3 | PI734B | PC 3.3 | – |
| C1675D5A | 1,500 | 1,675 | KTA50-GS8 | PI734D | PC 3.3 | – |
| C2000D5 | 1,875 | 2,063 | QSK60-G3 | PI734F | PC 3.3 | – |
| C2250D5 | 2,000 | 2,250 | QSK60-G4 | PI734G | PC 3.3 | – |
| C2500D5A | 2,250 | 2,500 | QSK60-G8 | LVSI804R | PC 3.3 | – |
* C22D5: Cummins’ rating card lists its standby rating below its prime rating, so we show the 22 kVA standby rating from Cummins’ product guide. We confirm ratings in every quote.
Which Cummins generator do I need?
Pick the set by its prime rating if it will run for long hours, and by its standby rating if it only covers grid outages. Add up the running load in kVA, allow for motor starting, and keep about 20 to 25% spare capacity.
- Up to 55 kVA: villas, shops, small offices and telecom sites (C22D5 to C55D5L)
- 90 to 550 kVA: buildings, workshops, warehouses and construction sites (C90D5 to C550D5)
- 700 kVA and above: factories, data centres, hospitals and paralleled plants (C700D5 to C2500D5A)
Not sure? Read prime vs standby ratings, or send us your load list and we’ll size it for you.
Supply, installation and service
MPS handles the whole job around the generator:
- Installation and commissioning
- Synchronization and ATS panels
- Cummins service, AMC and repairs
- Spare parts

Frequently asked questions
What sizes do Cummins diesel generators come in?
Cummins’ 50 Hz range runs from the C22D5 (22 kVA standby) to the C2500D5A (2,500 kVA standby), with 21 models in between.
What is the difference between the C-series model numbers?
The number is roughly the standby rating in kVA, and “D5” means diesel at 50 Hz. For example, the C110D5 is rated 110 kVA standby and 100 kVA prime.
Do you also sell Perkins generators?
Yes. MPS builds its own Perkins diesel generators from 10 to 2,750 kVA, with published fuel use, dimensions and noise for every model.
Need a Cummins generator?
Send the load, site and timeline, and we’ll recommend the right model.